sales office: 46 300 w factory road, addison il 60101 ? phone: (630) 628 - 9999 ? fax: (630) 628 - 9922 ? www.wabashtransformer.com split bobbin isolation transformer series: p24h - printed circuit mount, horizontal 6 pins ? power rating 1.1va to 36va ? single primary, 24v ? frequency 50/60hz ? series or parallel secondary ? dielectric strength C 2500 vrms ? insulation class b (130c) ? low capacitive coupling, no electrostatic shield needed agency approvals: ? ul/cul 5085 - 2 recognized (file e47299) ? insulation file no. e95662 va rating part number dimensions (inches) wgt. lbs secondary series parallel l w h ml a b c d (dia) 1.1 p24h - 11 - 24 24vct @ 46ma 12v @ 0.092a 1.38 1.13 0.93 - 0.250 0.250 1.22 - 0.17 2.4 p24h - 24 - 24 24vct @ 100ma 12v @ 0.200a 1.38 1.13 1.17 - 0.250 0.250 1.22 - 0.25 6 p24h - 06 - 24 24vct @ 250ma 12v @ 0.500a 1.63 1.31 1.29 1.06 0.250 0.350 1.28 0.125 0.44 12 p24h - 12 - 24 24vct @ 500ma 12v @ 1.000a 1.88 1.56 1.41 1.25 0.300 0.400 1.40 0.150 0.70 20 p24h - 20 - 24 24vct @ 833ma 12v @ 1.670a 2.25 1.88 1.41 1.66 0.300 0.400 1.59 0.218* 0.80 36 p24h - 36 - 24 24vct @ 1.500a 12v @ 3.000a 2.63 2.19 1.56 1.94 0.400 0.400 1.84 0.218* 1.10 * = slots indicates like polarity any application, any requirement, contact us for our custom designs single primary primaries and secondaries are designed to be used simultaneously. that is, they must be used either series or parallel connected (as one winding). same applies to secondaries also.
|